Last edited by Samusar
Sunday, May 10, 2020 | History

4 edition of Pathogen Destruction Efficiency in High Temperature Digestion found in the catalog.

Pathogen Destruction Efficiency in High Temperature Digestion

Werf Report Project 97-rem-2 (Werf Report)

by D. M. Gabb

  • 136 Want to read
  • 33 Currently reading

Published by IWA Publishing (Intl Water Assoc) .
Written in English

    Subjects:
  • Environmental Science,
  • Sewage treatment & disposal,
  • Science,
  • Environmental Studies,
  • Science/Mathematics,
  • Applied Sciences,
  • Environmental Engineering & Technology

  • The Physical Object
    FormatPaperback
    Number of Pages130
    ID Numbers
    Open LibraryOL8930553M
    ISBN 101843396963
    ISBN 109781843396963
    OCLC/WorldCa60529385

    Treatment of domestic sewage sludge is required to minimize the risk of adverse health effects from pathogens in biosolids applied to , EPA published regulations establishing the processes and conditions it deemed necessary to minimize these risks. Unlike the chemical standards, the pathogen regulations are not risk-based standards but are operational standards intended to reduce. TPAD1 system achieved the maximum methane production and pathogen destruction and it generated Class A biosolids according to Organic Matter Recycling Regulation of British Columbia at all operating SRTs, while the biosolids produced from the other digestion systems (control and TPAD2) could not meet the criteria for Class A and was classified Author: Bita Nazyab.

    ing anaerobic digestion system to operate as a TPAD system, in which the first digesters were operated in the thermophilic range (50–60 °C [– °F]) to promote pathogen destruction with the intent of producing Class A biosolids, while subsequent digesters were operated in the mesophilic range (30–38 °C [85– °F]) to re-.   The energy performance of the anaerobic digestion is depending mainly on the biogas production technology, raw materials and geographic location (ambient temperature). Since the feedstocks coming to anaerobic digestion have usually lower heating value as received, the usual energy efficiency calculation used for incineration plant is not by: 1.

    5. Cold weather efficiency 6. Nitrification/pH effects 7. Poor pathogen reduction Biochemical conversions in aerobic digesters include: Destruction of Biomass: C5H7O2N + 5O2 = 4CO2+H2O+NH4HCO3 NITRIFICATION OF RELEASED NH3‐N: NH4 ++2O 2+ = NO3‐+2H+ +H2O With complete nitrification.   Impacts of Anaerobic Digestion and Solid Liquid Separation on Pathogen Destruction 1. INACTIVATION OF DAIRY MANURE-BORNE PATHOGENSBYANAEROBIC DIGESTIONBecky Larson, Asli OzkaynakApril, 3, Mark Borchardt, Susan Spencer, and Spencer BorchardtUSDA –Agricultural Research ServiceUSGS Wisconsin Water Science Center 2.


Share this book
You might also like
1776-1876.

1776-1876.

false accusers of the brethren reproved and the accused instructed how to reply

false accusers of the brethren reproved and the accused instructed how to reply

Unless we become wise

Unless we become wise

Assignment of judges to the judicial district of New Mexico.

Assignment of judges to the judicial district of New Mexico.

Culled from our columns.

Culled from our columns.

Selangor Land Rules, 2003

Selangor Land Rules, 2003

Preschool practive workbook first words

Preschool practive workbook first words

Math Activities Using Logowriter

Math Activities Using Logowriter

Five year fiscal projections and revenue proposals of the Louisiana Department of Wildlife and Fisheries.

Five year fiscal projections and revenue proposals of the Louisiana Department of Wildlife and Fisheries.

Reasoning and argument in psychology

Reasoning and argument in psychology

Movement

Movement

Bolobolo

Bolobolo

Current Operative Urology 1991

Current Operative Urology 1991

Pathogen Destruction Efficiency in High Temperature Digestion by D. M. Gabb Download PDF EPUB FB2

Pathogen Destruction Efficiency in High-Temperature Digestion (Werf Report) [Gray (Gabb), Donald M., Hake, John M.] on *FREE* shipping on qualifying offers. Pathogen Destruction Efficiency in High-Temperature Digestion (Werf Report)Cited by: 1. The purpose of this research was to evaluate and compare various thermophilic anaerobic digestion processes for meeting U.S.

EPA biosolids Class A pathogen standards. The project was split into three phases. Phase 1 screened three bench-scale thermophilic anaerobic process configurations at three different thermophilic temperatures based on their fecal coliform destruction.

Pathogen destruction and process performance comparisons of the various process configurations are presented for each phase of the study. Based on the fecal coliform data presented here, an empirical model was developed for quantitatively comparing multiple stage and single-stage thermophilic anaerobic digester performance.

Pathogen Destruction Efficiency In High Temperature Digestion Donald M. Gray (Gabb) pages IWA Publishing. In fact, this project resulted in a patent that was obtained by WERF for a cost-effective process to produce pathogen-free Class A biosolids.

The project also presents comparable data on pathogen destruction and process performance for several thermophilic anaerobic digestion process configurations, and demonstrates at bench scale that two thermophilic anaerobic digestion process.

Free Online Library: Pathogen Destruction Efficiency in High-temperature Digestion: Final Report (ENVIRONMENTAL TECHNOLOGY, Brief Article, Book Review) by "SciTech Book News"; Publishing industry Library and information science Science and technology, general Books Book.

In Phase 3, the single-stage thermophilic anaerobic digestion process was compared to the single-stage mesophilic process at full scale (MG digesters) based on fecal coliform and pathogen destruction, process performance, digested sludge dewaterability, and odor generation.

The purpose of this research was to evaluate and compare various thermophilic anaerobic digestion processes for meeting U.S.

EPA biosolids Class A pathogen standards. The project was split into three phases. Phase 1 screened three bench-scale ther.

Pathogen Destruction Efficiency In High-Temperature Digestion. Date Published. Mar 5, Resource Type. Executive Summary. Pathogen Destruction Efficiency in High-Temperature Digestion. Report #97REM2PDF. 04/30/ 04/30/ West Quincy Avenue Denver, CO It combines the fundamental hydraulic, thermal and biokinetic mechanisms responsible for pathogen destruction during anaerobic digestion and has potential application as a tool for assessing the effects of operational management practices on the efficiency of pathogen removal by Cited by: Pathogen Destruction Efficiency in High-Temperature Digestion Since the advent of the U.S.

E nvironmental Protection Agency’s 40 CFR Pa rt Regulations in 1 9 9 3,more wa s t ewater utilities hav e focused on the use of thermophilic anaer-obic digestion (TAD) in the production of Class A biosolids. The higher tempera. The effect of temperature on pathogen survival was also reported by other researchers.

Iwasaki et al. () reported that after 12–15 day digestion, complete destruction of Coli-aerogenes and Enterococcus in a thermophilic biogas plant and a decline in the viable numbers in mesophilic by: 5.

Pris: kr. E-bok, Laddas ned direkt. Köp Pathogen Destruction Efficiency In High Temperature Digestion av Donald M D Gray på pathogen destruction required. Table 1 (p. 2) provides a brief introduction into some of the digester process options. Table 1. Common digester configurations Mesophilic digestion is by far the most common method of digestion, followed by thermophilic.

Other methods, such as. The survival of pathogens during anaerobic digestion is mainly influenced by the treatment temperature and the retention time with increasing temperature and retention time resulting in increasing. Table #A-3 contains information on the destruction of Listeria monocytogenes.

Lethal rate, as used in this table, is the relative lethality of one minute at the designated internal product temperature as compared to the lethality of one minute at the reference internal product temperature of ˚F (70˚C) (i.e.

z = ˚F [˚C]).File Size: KB. Pathogen Destruction Efficiency In High Temperature Digestion. Author(s): DM was to evaluate and compare various thermophilic anaerobic digestion processes for meeting U.S.

EPA biosolids Class A pathogen standards. The project was split Read more. DM Gabb RSS feed DM Gabb RSS feed. How to order. Agents. The latest from @IWApublishing. Pathogen destruction efficiency in high temperature digestion: WERF report (project REM-2).

[Donald M D Gray; John M Hake] -- The purpose of this research was to evaluate and compare various thermophilic anaerobic digestion processes for meeting U.S.

EPA biosolids Class A pathogen standards. Affecting Anaerobic Digestion Temperature Two distinct temperature ranges are most suitable for biogas production, and different bacteria operate in each of these ranges.

Mesophilic bacteria optimally fu n ct io he9 0˚F1 ra g.T m p l bacteria are most productive in the ˚F to ˚F range. Thermophilic digestion kills more pathogenicFile Size: KB. Although concentrations are typically over twice normal digestion, the additional load is approximately 20 to 30 percent higher when VS destruction is higher.

The biology of a THP anaerobic digester (THP-AD) is different than a conventional digester and is conditioned to both the high loading rates and high ammonia concentrations. During a thermal destruction process, such as pasteurization, the rate of destruction is logarithmic, as is their rate of growth.

but with the recognition of each new pathogen, the required time temperature relationships are continuously being examined. very high temperatures for very short times (e.g., oC for s) are favoured. Amongst the benefits presented by anaerobic digestion, it has also been associated with a reduction of pathogen occurring in cattle manure.

Inactivation of these zoonotic pathogens does occur under both temperature conditions, however; the degree of reduction in mesophilic temperature is lower compared to thermophilic temperatures [ ].Cited by: The mesophilic bacteria used in digestion can function at a range of 85 degrees F.

to degrees F. with the optimum range for normal digestion at 90 degrees F. to 98 degrees F. Advanced Anaerobic Digestion Study Guide - June EditionFile Size: KB.